The CONNECTION_INPUT tag array is used to receive a copy of the data from the
I/O input image data block and bring that data into the AOI logic for processing.
The CONNECTION_OUTPUT tag array is used to send data to the I/O output image
data block after the AOI logic has finished its logic processing.
For information on the GSC array, see Controller Tags (page 104).
AOI56GSC Local Tags Tab
The MJFAULTS tag array defined in this tab is used by the AOI Prescan routine
for module initialization. This tag array has little practical use for user-specific
applications. It is recommended that you make no changes to the selections and
entries on this tab.