General Specifications
ProLinx
®
Communication Gateways provide connectivity for two or more
dissimilar
network types. The gateways, encased in sturdy extruded aluminum, are
stand-alone
DIN-rail-mounted solutions that provide data transfer between many of today’s
most
widely used industrial
automation.
Modbus TCP/IP
ProSoft's Modbus TCP/IP implementation uses the gateway's shared internal
memory
database for data transfer. Sharing the memory database with another protocol
driver
allows the gateway to transfer data between Modbus TCP/IP devices and other
devices
on other
networks.
Configurable floating point data movement is supported, including support for Enron
or
Daniel
®
floating point
applications.
Modbus TCP/IP Server (Slave)
The server driver accepts incoming connections on Service Port 502 for clients
using
Modbus TCP/IP MBAP messages and from clients on Service Port 2000 (or
other
Service Ports) for clients using Encapsulated Modbus
messages..
Supports five independent server connections for Service Port 502
(MBAP)
Supports five independent server connections for Service Port 2000
(Encapsulated)
The Modbus TCP/IP implementation in this gateway has been specially
designated
to meet the unique requirements of the 3964R protocol. This provides a more
tightly
integrated solution for data transfer between the two
protocols.
Modbus data types overlap in the gateway's memory database, so the same
data
can be conveniently read or written as bit-level or register-level
data.
Modbus TCP/IP Client (Master)
Actively reads data from and writes data to Modbus TCP/IP devices, using
MBAP
or Encapsulated Modbus message
formats
Offers one client connection with up to 100 commands to talk to multiple
severs
Status Data
Error codes, counters, and port status
available
S3964R
Supported baud rates: 600 through 19200 are typical; up to 115200 is
possible
Supported protocols: 3964 with RK512, 3964 without
RK512
Priority setting to define the behavior of the protocol in case of an
initialization
conflict.
Offers four independently configurable serial ports. Each port can
communicate
using 3964R protocol with or without RK512 formatting. Each port can be set to
use
an RS-232 or RS-422 serial signal interface. The ports operate independently
from
each other and each port is assigned its own space in the gateway's user
memory
database.
When using S3964R without RK512 communications mode, Port 0, Port 1, Port
2,
and Port 3 can initiate or receive DB-SEND
instructions.
RK512 mode on Port 0, Port 1, Port 2, and Port 3 allow evaluation of RK512
header
information: DB data block, DW data word, Coordination Byte 9, and
CPU
Coordination Byte
10.
When using S3964R without RK512 communications mode, Port 0, Port 1, Port
2,
and Port 3 can send or receive standard communication telegrams
(message
packets).
In either mode, 512 bytes is the maximum amount of data transferred per
data
transfer
operation
Data byte order can be swapped to support different device-specific word
formats
Communication activity indications and diagnostic information are available
through
LEDs and acknowledgment
telegrams.
Schematic