RLXIC-EH Intelligent Cellular Data Communication and Host Modes
RadioLinx Intelligent Cellular Ethernet Gateway for HSUPA (3G GSM) Networks User Manual
Page 56 of 111 ProSoft Technology, Inc.
May 29, 2009
Note: This feature can be used only in private mode.
In AceManager, enter the fields in the Port Forwarding group.
Number of PF Entries: Set value to number of used Port forward rules for
performance gain. Each forwarding entry has four parameters:
o Public Port: Port number of the Modem/Gateway.
o Host/IF: Physical connection type to the modem. (USB, Ethernet, Serial).
o Host IP: IP address of the connected device/computer.
o Private Port: Port number on the connected device.
You can set a default in the PPP/Ethernet group, if you do not need: