3.2 Adding the Module to an Existing Project
1 Select the I/O Configuration folder in the Controller Organization window of RSLogix
5000, and then click the right mouse button to open a shortcut menu. On the shortcut
menu, choose N
EW
M
ODULE
.
This action opens the Select Module dialog box:
2 Select the 1756-M
ODULE
(G
ENERIC
1756
M
ODULE
) from the list and click OK. This
action opens the New Module dialog box.
3 Enter the Name, Description and Slot options for your application. You must select
the Comm Format as D
ATA
-
INT in the dialog box, otherwise the module will not
communicate. Click OK to continue.
Parameter Value
Name
Enter a module identification string. Example: HART_2