Water Industry
MetOne PCX Water Master Connectivity
Example Application: User requires an interface between a PLC-5 and
MetOne Particle Counting Sensors.
Solution: 3100-PCX for PLC-5
MTS Level Plus Interface Module
• Widely used in water applications to measure level, interface,
and temperature simultaneously
• Support for up to 64 MTS Level Plus sensors
Example Application: User requires an interface between Rockwell
Automation processors and MTS Level Plus Sensors.
Solution: 3150-MTS for SLC 500
3100-MTS for PLC-5
Power Industry
Harris 5000/5500/6000 RTU Slave Connectivity
• Applications are found mainly in the power industry: foreign
device data concentrators, power equiment monitoring and dam
operation
Example Application: User requires an interface between Rockwell
Automation processors and Harris M9000 Host-based system.
Solution: 3100-HAR for PLC-5™
3150-HAR for SLC™ 500
ASCII Communications
Honeywell 7800 Series
Master Connectivity
• Supports up to 32 Honeywell nodes per
serial port
•Two fully congurable serial ports, each
capable of supporting the CBM Master
functionality using the ASCII mode of
communications
Example Application: User requires an interface between Rockwell
Automation processors and Honeywell 7800 Series Burner Management
hardware devices.
Solution: 3100-CBM for PLC-5
3150-CBM for SLC 500
Landis & Gyr Telegyr 8979F Connectivity
• SCADA systems supporting this application are found in the
power utility industry
Example Application: User requires a gateway between Telegyr 8979 Rev. F
version of the protocol and the Allen-Bradley backplane.
Solution: MVI46-LNG for SLC 500
MVI56-LNG for ControlLogix™
3100-LNG for PLC-5
Baggage Handling
Siemens 3964R Connectivity
• The solution can be used in a local I/O rack (SLC), or in a local/
remote rack for the ControlLogix or PLC5
• The 3964R protocol was designed by Siemens for
bi-directional data communication through a point-to-point
connection. It is a peer-to-peer protocol with read and write
access
Example Application: User requires point-to-point communication between
a Rockwell Automation controller and a partner with 3964R (with or without
RK512) communication capability.
Solution: MVI46-3964R for SLC 500
MVI56-3964R for ControlLogix
MVI71-3964R for PLC-5
Command Language Master Connectivity for
SICK Barcode
• Compatible devices include SICK® Barcode
Scanners supporting Command Language
Protocol
Example Application: User requires a communication
interface between the ControlLogix processor and SICK
barcode scanner devices.
Solution: MVI56-CLVM for ControlLogix
Allen-Bradley SLC
with ProSoft
3150 CBM Module
Honeywell
7800 series
Honeywell
BCS 7700 Series
ControlLogix
with ProSoft
SICK Barcode
Scanner
17