5204SE-MNET-PDPMV1 ProLinx Gateway Reference
Modbus TCP/IP to PROFIBUS DP-V1 Pass-Through Master User Manual
Page 110 of 235 ProSoft Technology, Inc.
December 22, 2009
MNETDPV1_StatIn Variables - M340
These variables take advantage of the StatInF DDT structure. The GetStatus
DFB will automatically populate this variable list with general gateway status
information received in the Modbus TCP/IP response to the GetModuleStatus
command.
The %MW addresses shown are for illustration only. If you decide to use these
variables, your application may require that you map them to addresses other
than the ones shown here. You may assign these variables to any valid %MW
addresses that exist in your processor configuration by setting the desired start
address in the PLC
STATUS REGISTER START parameter in the PCB configuration
file. This will cause the import files to contain addresses in the range you select
and change the values displayed in this array.