CIP API Functions ControlLogix Platform "C" Programmable
Developer's Manual Linux Application Development Module
Page 188 of 264 ProSoft Technology, Inc.
March 12, 2014
OCXcip_SetLED3
Syntax
int OCXcip_SetLED3 (OCXHANDLE apihandle, int * ledstate);
Parameters
apihandle
handle returned by previous call to OCXcip_Open
ledstate
Specifies the state for the LED
Description
OCXcip_SetLED3 allows an application to set the err LED indicator to Red, Green,
or Off.
apihandle must be a valid handle returned from OCXcip_Open.
ledstate must be set to:
OCX_LED_STATE_RED,
OCX_LED_STATE_GREEN, or
OCX_LED_STATE_OFF
to set the indicator Red, Green, or Off respectively.
Return Value
OCX_SUCCESS
The LED was set successfully
OCX_ERR_NOACCESS
apihandle does not have access
OCX_ERR_BADPARAM
ledstate is invalid
Example
OCXHANDLE apiHandle;
/* Set err LED to Off */
OCXcip_SetLED3 (apiHandle, OCX_LED_STATE_OFF);