Block Request from Processor to Module
M1 Offset Description Length
7800 3000 or 3100 1
7801 Number of Slaves in Block 1
7802 to 7927 Slave Indexes 126
The module will respond with a block with the same identification code received
and indicate the number of slaves acted on with the block.
Block Response from Module to Processor
M0 Offset Description Length
0 3000 or 3100 1
1 Number of Slaves Processed 1
Ladder logic can be written to override the value in the slave status table to
enable the slave (state value of 1) by sending a special block. Port 1 slaves are
enabled using block 3001, and Port 2 slaves are enabled using block 3101. Each
block contains the slave node addresses to enable.
Block Request from Processor to Module
M1 Offset Description Length
7800 3001 or 3101 1
7801 Number of Slaves in Block 1
7802 to 7927 Slave Indexes 126
The module will respond with a block with the same identification code received
and indicate the number of slaves acted on with the block.
Block Response from Module to Processor
M0 Offset Description Length
0 3001 or 3101 1
1 Number of Slaves Processed 1