AN-X-AMXRIO Communication Module for Reliance AutoMax Remote I/O User Manual

Seite 2

Page 6 AN-X-AMXRIO November 2011 The cable must be RG-59/U. Ethernet Cabling AN-X has a standard RJ-45 connector for connecting to Ethernet. I

Seite 3

AN-X-AMXRIO Page 7 Ethernet Configuration The AN-X-AMXRIO module connects a computer or other device on Ethernet to a Reliance AutoMax remote I/O n

Seite 4

Page 8 AN-X-AMXRIO November 2011 If AN-X does not find a DHCP server within about three minutes of starting up, it reverts to a temporary stati

Seite 5

AN-X-AMXRIO Page 9 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the compu

Seite 6 - AN-X-AMXRIO Module Overview

Page 10 AN-X-AMXRIO November 2011 Step 3: Wait for AN-X to enter boot mode. While AnxInit is waiting, the Next>> button will be disabled

Seite 7 - Modes of Operation

AN-X-AMXRIO Page 11 Enter a Host Name for the AN-X. This name is used internally by AN-X and may be used to identify the AN-X if you have a DNS s

Seite 8

Page 12 AN-X-AMXRIO November 2011 AutoMax Remote I/O Configuration You set the remote I/O configuration using the web interface. The remote I/O

Seite 9 - Installation

AN-X-AMXRIO Page 13 TIP To view the current configuration, it may be necessary to refresh the displayed configuration once or twice, as the browse

Seite 10 - Software Installation

Page 14 AN-X-AMXRIO November 2011 • the starting output and input offsets in the ControlLogix scheduled data for the drop. Drops must start o

Seite 11 - Ethernet Configuration

AN-X-AMXRIO Page 15 Example ;OutLen,InpLen ;64,64

Seite 12

Page 2 AN-X-AMXRIO November 2011 Because of the variety of uses for the products described in this publication, those responsible for the appl

Seite 13 - AN-X-AMXRIO Page

Page 16 AN-X-AMXRIO November 2011 Scheduled Data with a ControlLogix AN-X-AMXRIO exchanges scheduled data with a ControlLogix processor. It su

Seite 14

AN-X-AMXRIO Page 17 while the AN-X is exchanging scheduled data with a ControlLogix processor in a production environment, because this affects the

Seite 15

Page 18 AN-X-AMXRIO November 2011 7. Set the Input Assembly Instance to 1. Normally you set the size to the maximum allowed, 250 words. You

Seite 16

AN-X-AMXRIO Page 19 Configuring Input-Only Connections In a ControlLogix system, multiple processors can receive inputs from a module. Only one pr

Seite 17 - Configuration File Format

Page 20 AN-X-AMXRIO November 2011 Connection Parameters 12. Set the module Requested Packet Interval (RPI). This is how often the module’s s

Seite 18

AN-X-AMXRIO Page 21 Input and Output Data The tag file contains the location of the scheduled input and output data for all I/O modules and registe

Seite 19

Page 22 AN-X-AMXRIO November 2011 Offset Description 20 Reserved 21 ControlLogix input average update time for previous 100 updates 22 Cont

Seite 20 - Reference

AN-X-AMXRIO Page 23 If the log overflows, AN-X closes the log file (enetip.0) and opens a second log file (enetip.1) and continues to alternate b

Seite 21

Page 24 AN-X-AMXRIO November 2011 Connection Tab The Inhibit Module checkbox inhibits the module. It should not be checked for normal operatio

Seite 22

AN-X-AMXRIO Page 25 Creating ControlLogix Tags Use the AmxRioTagExport utility to create tags that can be imported into RSLogix 5000. These tags ar

Seite 23

AN-X-AMXRIO MODULE OVERVIEW 2 Hardware Features 3 Package Contents 3 Other Requirements 3 Modes of Operation 3 INSTALLATION 5 Prevent Electros

Seite 24 - Locating the Data

Page 26 AN-X-AMXRIO November 2011 To import the file into RSLogix 5000: 1. Select Tools/Import Tags. 2. Browse or type in the tag file name

Seite 25 - Status Input Data

AN-X-AMXRIO Page 27 followed by the slot and offset. For example, the name AmxRack1_O_04_16 corresponds to rack 1 output, slot 4, offset 16. You c

Seite 26 - Error Log

Page 28 AN-X-AMXRIO November 2011 Using AnxInit AnxInit is a 32-bit Windows application supplied with AN-X to perform the following functions:

Seite 27 - General Tab

AN-X-AMXRIO Page 29 AN-X Log Locating Available AN-X Modules To locate all accessible AN-X modules on the Ethernet network, select Utilities/Locat

Seite 28 - Connection Tab

Page 30 AN-X-AMXRIO November 2011 Selecting an AN-X Before you can perform an operation on an AN-X, you must select it. Choose Utilities/Sel

Seite 29 - Creating ControlLogix Tags

AN-X-AMXRIO Page 31 In the IP Address field, enter the Ethernet IP address of the AN-X you wish to select. It can be found using the Locate All AN

Seite 30 - Tag File Format

Page 32 AN-X-AMXRIO November 2011 • the Subnet mask for the AN-X • the default gateway for your network. You must enter a valid default gat

Seite 31

AN-X-AMXRIO Page 33 Possible status values are: Value Meaning 1 Boot mode 2 Configuration mode 4 Production mode Read Kernel Parameters The Ut

Seite 32 - Using AnxInit

Page 34 AN-X-AMXRIO November 2011 This command resets the AN-X. You will receive a warning and be given the opportunity to Cancel the command.

Seite 33

AN-X-AMXRIO Page 35 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the com

Seite 34 - Selecting an AN-X

Page 4 AN-X-AMXRIO November 2011 Error Log 22 Using RSLogix 5000 to Diagnose Problems 23 General Tab 23 Connection Tab 24 CREATING CONTROLL

Seite 35 - Set AN-X IP Configuration

Page 36 AN-X-AMXRIO November 2011 The preferred method is to cycle power on the AN-X. Select the first option on the screen and click the Ne

Seite 36 - AN-X Info

AN-X-AMXRIO Page 37 If the AN-X does not enter config mode within about 60 seconds, return to the previous screens and check the entries. Click t

Seite 37 - Update AN-X Flash

Page 38 AN-X-AMXRIO November 2011 • AN-X to AN-X configuration Update Firmware Command The Utilities/Update Firmware command updates all the

Seite 38 - Update Firmware

AN-X-AMXRIO Page 39 You do not have to reconfigure the AN-X after applying a patch. All configuration information will be left intact. When the pa

Seite 39

Page 40 AN-X-AMXRIO November 2011 Using the Web Interface The AN-X module contains a webserver capable of communicating with standard web brows

Seite 40

AN-X-AMXRIO Page 41 Remote I/O Configuration To set the remote I/O configuration using the web interface, the remote I/O network must be connected

Seite 41

Page 42 AN-X-AMXRIO November 2011 previously cached version of the file. To save the configuration file, right click the View AutoMax RIO Ethe

Seite 42 - Patch Firmware

AN-X-AMXRIO Page 43 Administration Menu The Administration Menu is used to set the AN-X IP address and to view and edit files on AN-X. The file ed

Seite 43

Page 44 AN-X-AMXRIO November 2011 You can configure the AN-X to use DHCP or to use a static IP address. Click SUBMIT to set the parameters

Seite 44 - Using the Web Interface

AN-X-AMXRIO Page 45 Troubleshooting LEDs The AN-X-AMXRIO has LEDs that indicate the state of the Ethernet connection, the connection to the AutoM

Seite 45 - Remote I/O Configuration

Administration Menu 43 Browse File System 43 AN-X IP Configuration 43 Archive Configuration 44 TROUBLESHOOTING 45 LEDs 45 Ethernet LEDs 45 SYS

Seite 46 - Log Files

Page 46 AN-X-AMXRIO November 2011 • boot code loads a kernel – solid red • if the configuration kernel is loaded, 2 red flashes followed by a

Seite 47 - Administration Menu

AN-X-AMXRIO Page 47 Updating the Firmware The AN-X operating software consists of several parts: • boot code, runs at startup • configuration ker

Seite 48 - Archive Configuration

Page 48 AN-X-AMXRIO November 2011 AutoMax Remote I/O Network The remote I/O network can contain up to 7 drops, numbered 1 to 7. Each drop can

Seite 49 - Troubleshooting

AN-X-AMXRIO Page 49 Specifications Parameter Specification Function Bridge between Ethernet and AutoMax remote I/O network Description Processor

Seite 50 - NET LED – Network Status

Page 50 AN-X-AMXRIO November 2011 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by Pr

Seite 51 - Updating the Firmware

AN-X-AMXRIO Page 51 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material under normal use an

Seite 52 - AutoMax Remote I/O Network

AN-X-AMXRIO Module Overview This document is a user guide for the AN-X-AMXRIO communications module, which connects a computer or other device to a

Seite 53 - Specifications

AN-X-AMXRIO Page 3 Hardware Features The module has: • LEDs to indicate the status of the connection to the Ethernet, its own internal state, a

Seite 54 - Support

Page 4 AN-X-AMXRIO November 2011 • Configuration mode. This is the mode when you are updating the firmware in the AN-X. • Production mode. T

Seite 55 - Warranty

AN-X-AMXRIO Page 5 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! Electrostatic dischar