Prosoft-technology AN-X-AMX Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Relais Prosoft-technology AN-X-AMX herunter. ProSoft Technology AN-X-AMX User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

AN-X-DCSNet2 Communication Module User Manual

Seite 2

Page 6 AN-X-DCSNet2 November 2011 The passive tap has two BNC connectors for connection to the coaxial cables and terminating loads. The network

Seite 3

AN-X-DCSNet2 Page 7 Ethernet Configuration The AN-X-DCSNet2 module connects a computer or other device on Ethernet to a Reliance DCS network. Befor

Seite 4

Page 8 AN-X-DCSNet2 November 2011 AN-X is using this temporary IP address, it repeatedly flashes the SYS LED three times followed by a pause.

Seite 5

AN-X-DCSNet2 Page 9 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the com

Seite 6 - AN-X-DCSNet2 Module Overview

Page 10 AN-X-DCSNet2 November 2011 The preferred method is to cycle power on the AN-X. Select the first option on the screen, power off the A

Seite 7 - Other Requirements

AN-X-DCSNet2 Page 11 If the AN-X does not enter boot mode within about 10 seconds, return to the previous screens and check the entries. The AN-

Seite 8 - Modes of Operation

Page 12 AN-X-DCSNet2 November 2011 Enter a Host Name for the AN-X. This name is used internally by AN-X and may be used to identify the AN-X if

Seite 9 - Installation

AN-X-DCSNet2 Page 13 Click the Properties button. Double click on Internet Protocol (TCP/IP).

Seite 10 - Software Installation

Page 14 AN-X-DCSNet2 November 2011 In this example, we will assign the computer an IP address of 192.168.0.10 Set the Subnet mask to 255.255.255

Seite 11 - Ethernet Configuration

AN-X-DCSNet2 Page 15 Select Utilities/Select An AN-X and enter the MAC Address and IP address. Click OK to accept the setting. Select Utilities/AN

Seite 12

Page 2 AN-X-DCSNet2 November 2011 Because of the variety of uses for the products described in this publication, those responsible for the appl

Seite 13 - AN-X-DCSNet2 Page

Page 16 AN-X-DCSNet2 November 2011 Reconfiguring an AN-X from an Unknown State It sometimes happens that an AN-X has been previously configure

Seite 14

AN-X-DCSNet2 Page 17 DCSNet Configuration You set the DCS mode of operation (master or slave) and the drop number and depth using the web interface

Seite 15

Page 18 AN-X-DCSNet2 November 2011 Using the AutoMax Programming Software Any computer with Ethernet access can use an AN-X-DCSNet module to con

Seite 16 - Example: Standalone Computer

AN-X-DCSNet2 Page 19 Configuring the Programming Software To configure the AutoMax Programming Executive to use AN-X: 1. Run the Programming Exe

Seite 17 - Click the Properties button

Page 20 AN-X-DCSNet2 November 2011 3. Set the Communications Type to PC Link Interface Module. 4. Set the Drop to match the AN-X drop number

Seite 18

AN-X-DCSNet2 Page 21 If multiple copies of the Programming Executive attempt to program an AutoMax through the same AN-X-DCSNet, the AutoMax sees t

Seite 19

Page 22 AN-X-DCSNet2 November 2011 Scheduled Data with a ControlLogix AN-X-DCSNet2 exchanges scheduled data with a ControlLogix processor. It su

Seite 20

AN-X-DCSNet2 Page 23 2. Map DCS data to the scheduled data and save the mappings as a comma separated variable (CSV) file 3. Send the configurati

Seite 21 - DCSNet Configuration

Page 24 AN-X-DCSNet2 November 2011 Enter the Name. Use the host name you assigned to AN-X when you configured its IP properties. Set the Slot

Seite 22 - Requirements

AN-X-DCSNet2 Page 25 Set the Name and Description as desired. Set the Comm Format to Data – INT. Set the other parameters as shown. Set the Slot

Seite 23

AN-X-DCSNET2 MODULE OVERVIEW 2 Hardware Features 3 Package Contents 3 Other Requirements 3 Modes of Operation 4 INSTALLATION 5 Prevent Electro

Seite 24 - Multiple Programmer Access

Page 26 AN-X-DCSNet2 November 2011 AN-X supports RPIs from 5 to 750 ms. Select an RPI appropriate to the DCS network scan time and to your app

Seite 25

AN-X-DCSNet2 Page 27 Input Only Connection The AN-X-DCSNET2 supports one input only connection from a ControlLogix processor. The ControlLogix pro

Seite 26

Page 28 AN-X-DCSNet2 November 2011 Set the parameters as shown. Set the Comm Format to Input Data – INT. Set the Slot to 0 for the first c

Seite 27 - Reference

AN-X-DCSNet2 Page 29 Mapping the DCS Data You define the DCS data that is exchanged between the AN-X and the ControlLogix processor in a comma-d

Seite 28

Page 30 AN-X-DCSNet2 November 2011 The ClxPrefix can be used to distinguish between AN-X modules when a ControlLogix processor communicates with

Seite 29

AN-X-DCSNet2 Page 31 depth. For example, if the drop number is 7 and the depth is 3, only drops 7, 8, and 9 can be used in output data mappings. I

Seite 30

Page 32 AN-X-DCSNet2 November 2011 The units for the times are 0.1 milliseconds. A value of 87 means 8.7 ms. To map the statistics for a given

Seite 31 - Input Only Connection

AN-X-DCSNet2 Page 33 ,ConnStats15 Sample File – DCS Master The following sample file shows how data is mapped for an AN-X configured as a DCS mast

Seite 32

Page 34 AN-X-DCSNet2 November 2011 Viewing the Current Configuration To view the configuration in an AN-X module, access the AN-X using the web

Seite 33 - Mapping the DCS Data

AN-X-DCSNet2 Page 35 In the web interface, select Automation Network/View Configuration Files. There are two sets of files, one for exclusive owner

Seite 34 - I/O Data

Page 4 AN-X-DCSNet2 November 2011 Reference 23 Configuring AN-X in RSLogix 5000 23 Exclusive Owner Connection 23 Input Only Connection 27 Ma

Seite 35

Page 36 AN-X-DCSNet2 November 2011 Using AnxInit AnxInit is a 32-bit Windows application supplied with AN-X to perform the following functions:

Seite 36 - Sample File – DCS Slave

AN-X-DCSNet2 Page 37 AN-X Log Locating Available AN-X Modules To locate all accessible AN-X modules on the Ethernet network, select Utilities/Loc

Seite 37 - Sample File – DCS Master

Page 38 AN-X-DCSNet2 November 2011 Selecting an AN-X Before you can perform an operation on an AN-X, you must select it. Choose Utilities/Sele

Seite 38 - Exporting Aliases from AN-X

AN-X-DCSNet2 Page 39 Enter a Host Name for the AN-X. This name is used internally by AN-X and may be used to identify the AN-X if you have a DNS

Seite 39 - Connection Tab

Page 40 AN-X-DCSNet2 November 2011 AN-X Info The Utilities/AN-X Info command provides information about the currently selected AN-X in the log

Seite 40 - Using AnxInit

AN-X-DCSNet2 Page 41 The Utilities/Read Kernel Parameters command leaves the AN-X running the boot code. Use the Utilities/Restart AN-X command t

Seite 41

Page 42 AN-X-DCSNet2 November 2011 Update Firmware There are two ways to update all the firmware in an AN-X module. 1. The Configuration/Firm

Seite 42 - Set AN-X IP Configuration

AN-X-DCSNet2 Page 43 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the co

Seite 43 - Restart an AN-X

Page 44 AN-X-DCSNet2 November 2011 The preferred method is to cycle power on the AN-X. Select the first option on the screen and click the Ne

Seite 44 - Read Kernel Parameters

AN-X-DCSNet2 Page 45 If the AN-X does not enter config mode within about 60 seconds, return to the previous screens and check the entries. Click

Seite 45 - Update AN-X Flash

USING THE WEB INTERFACE 48 DCSNet Configuration 48 Configure ControlLogix Support 50 View Configuration Files 50 View Active Configuration 51 Mo

Seite 46 - Update Firmware

Page 46 AN-X-DCSNet2 November 2011 • ControlLogix configuration Update Firmware Command The Utilities/Update Firmware command updates all the

Seite 47

AN-X-DCSNet2 Page 47 This command resets the AN-X. You will receive a warning and be given the opportunity to Cancel the command. You do not h

Seite 48

Page 48 AN-X-DCSNet2 November 2011 Using the Web Interface The AN-X module contains a webserver capable of communicating with standard web brows

Seite 49

AN-X-DCSNet2 Page 49 AN-X-DCSNet can be used as a DCS master or slave. Check Master or Slave to select which one you want. If the AN-X-DCSNet is

Seite 50 - Patch Firmware

Page 50 AN-X-DCSNet2 November 2011 Configure ControlLogix Support AN-X can exchange scheduled data with a ControlLogix processor over Ethernet.

Seite 51

AN-X-DCSNet2 Page 51 Click on the links to view the files using the application that is associated with CSV files. Right click on the links to ret

Seite 52 - Using the Web Interface

Page 52 AN-X-DCSNet2 November 2011

Seite 53

AN-X-DCSNet2 Page 53 Monitor DCS Data To use the web interface to view the current DCS network data on the AN-X, select Automation Network/Monitor

Seite 54 - View Configuration Files

Page 54 AN-X-DCSNet2 November 2011 Log Files AN-X maintains various logs to record diagnostic and error messages. Use the Log Files menu in the

Seite 55 - View Active Configuration

AN-X-DCSNet2 Page 55 Technical support will provide the password and supply detailed information on any further steps. AN-X IP Configuration You

Seite 56

AN-X-DCSNet2 Module Overview The AN-X-DCSNet2 firmware runs on an AN-X AutoMax communications module and connects a computer or other device to a Re

Seite 57 - Monitor DCS Data

Page 56 AN-X-DCSNet2 November 2011 You can configure the AN-X to use DHCP or to use a static IP address. Click SUBMIT to set the parameters

Seite 58 - Administration Menu

AN-X-DCSNet2 Page 57 Restart AN-X Module The Restart AN-X Module command is password protected and is intended for technical support.

Seite 59 - AN-X IP Configuration

Page 58 AN-X-DCSNet2 November 2011 Troubleshooting LEDs The AN-X-DCSNet has LEDs that indicate the state of the Ethernet connection, the conne

Seite 60 - Archive Configuration

AN-X-DCSNet2 Page 59 At startup, the SYS LED sequence is: • boot code starts – fast flashing red • boot code loads a kernel – solid red • if the

Seite 61 - Restart AN-X Module

Page 60 AN-X-DCSNet2 November 2011 In the drop status table, register 4 contains status for drops 0 to 15, bit 0 corresponds to drop 0 (the mas

Seite 62 - Troubleshooting

AN-X-DCSNet2 Page 61 Updating the Firmware The AN-X operating software consists of several parts: • boot code, runs at startup • configuration ke

Seite 63 - DCS Diagnostic Counters

Page 62 AN-X-DCSNet2 November 2011 Specifications Parameter Specification Function Bridge between Ethernet and AutoMax DCS network Typical Po

Seite 64

AN-X-DCSNet2 Page 63 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by ProSoft Technology.

Seite 65 - Updating the Firmware

Page 64 AN-X-DCSNet2 November 2011 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material u

Seite 66 - Specifications

AN-X-DCSNet2 Page 3 Hardware Features The module has: • LEDs to indicate the status of the connection to the Ethernet, its own internal state,

Seite 67 - Support

Page 4 AN-X-DCSNet2 November 2011 To exchange scheduled data with a ControlLogix processor over Ethernet requires: • version 12 or above of RSL

Seite 68 - Warranty

AN-X-DCSNet2 Page 5 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! Electrostatic discha

Kommentare zu diesen Handbüchern

Keine Kommentare