Prosoft-technology AN-X-AMX Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Relais Prosoft-technology AN-X-AMX herunter. ProSoft Technology AN-X-AMX User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

AN-X-AMXCAPT AutoMax Capture Module User Manual

Seite 2

Page 6 AN-X-AMXCAPT January 2008 Basic Configuration The AN-X-AMXCAPT module connects a computer or other device on Ethernet to a Reliance Auto

Seite 3

AN-X-AMXCAPT Page 7 IMPORTANT! Use this temporary IP address only for initial setup of AN-X. AN-X will not function for its intended purpose at t

Seite 4

Page 8 AN-X-AMXCAPT January 2008 If the AN-X is already online, you can obtain its MAC address using the Utilities/Locate All AN-X Modules comm

Seite 5

AN-X-AMXCAPT Page 9 If the AN-X does not enter boot mode within about 10 seconds, return to the previous screens and check the entries. The AN-

Seite 6 - AN-X-AMXCAPT Module Overview

Page 10 AN-X-AMXCAPT January 2008 To configure the AN-X to obtain its IP address from a DHCP server on the network, select Obtain an IP address

Seite 7 - Modes of Operation

AN-X-AMXCAPT Page 11 Capturing and Displaying Network Data Use the Windows AnxAmxCapt utility to capture network frames, transfer them from the A

Seite 8 - Installation

Page 12 AN-X-AMXCAPT January 2008 capture, and the error limit is not 0, the error count is reset to 0 each time a new file is opened. TIP You

Seite 9 - Software Installation

AN-X-AMXCAPT Page 13 It shows the current time, the file currently being used to store the capture data, the file size, the file being deleted (

Seite 10 - Basic Configuration

Page 14 AN-X-AMXCAPT January 2008 Browse or type the capture file name into the FileName box. AnxAmxCapt appends the option file name to the

Seite 11 - AN-X-AMXCAPT Page 7

AN-X-AMXCAPT Page 15 Option Files Option files are used to define which frames are extracted from captured data. Option files consist of various

Seite 12

Page 2 AN-X-AMXCAPT January 2008 Because of the variety of uses for the products described in this publication, those responsible for the appli

Seite 13 - AN-X-AMXCAPT Page 9

Page 16 AN-X-AMXCAPT January 2008 357: a 0:00.748,593 *255< 05^ 55- 00 00 00 00 00 To suppress the inclusion of frames with bad status, inc

Seite 14

AN-X-AMXCAPT Page 17 TIP You can use the delta time to display update times for a drop. Modify the option file QTS_UpdFromDrop.opt to display th

Seite 15 - Capturing Network Frames

Page 18 AN-X-AMXCAPT January 2008 9: a 0:00:00.023,297 g 1,053 g... | 10: a 0:00:00.029,659 g 0,176 g

Seite 16

AN-X-AMXCAPT Page 19 Frame Data Detailed Status If the DetailSts option line is present, detailed status information is displayed for each frame.

Seite 17 - Selecting Frames of Interest

Page 20 AN-X-AMXCAPT January 2008 Integer 4: a 0.004,958 g... | 255< 05^ 55- 4660 -1 13107… Unsigned integer 4: a 0.0

Seite 18

AN-X-AMXCAPT Page 21 Keyword Description GapTme Gap time, see page 16 Frame Status, STS The frame status can be one of the following: Value Symbo

Seite 19 - Option Files

Page 22 AN-X-AMXCAPT January 2008 For I/O updates the destination is 255 (broadcast) since all drops see updates to and from all other drops. E

Seite 20 - Timestamps

AN-X-AMXCAPT Page 23 showonly ((CTL&0x0F)= CTL_UPDTOMAS) AND (drop = 2) # Data Values, DataByte[ofs] and DataWord[ofs] Offsets start from 0 a

Seite 21 - AN-X-AMXCAPT Page 17

Page 24 AN-X-AMXCAPT January 2008 Format Data range Signed integer -32768 to 32767 Hexadecimal 0x0000 to 0xFFFF Passing In Parameters You ca

Seite 22

AN-X-AMXCAPT Page 25 Operator Description > greater than < less than && logical AND AND logical AND || logical OR OR logical OR ! lo

Seite 23 - Frame Data

AN-X-AMXCAPT MODULE OVERVIEW 2 Hardware Features 2 Package Contents 3 Other Requirements 3 Modes of Operation 3 INSTALLATION 4 Prevent Electro

Seite 24 - Equations

Page 26 AN-X-AMXCAPT January 2008 Captured Data Format The following sample output shows a capture from DCSNet, selected using the sample optio

Seite 25 - AN-X-AMXCAPT Page 21

AN-X-AMXCAPT Page 27 After the header is the frame I/O data. On updates from the master, the first data on every update is the global broadcast d

Seite 26

Page 28 AN-X-AMXCAPT January 2008 Using AnxInit AnxInit is a 32-bit Windows application supplied with AN-X to perform the following functions:

Seite 27 - Constants

AN-X-AMXCAPT Page 29 AN-X Log Locating Available AN-X Modules To locate all accessible AN-X modules on the Ethernet network, select Utilities/Loc

Seite 28 - Operators

Page 30 AN-X-AMXCAPT January 2008 Selecting an AN-X Before you can perform an operation on an AN-X, you must select it. Choose Utilities/Sel

Seite 29 - Sample Option Files

AN-X-AMXCAPT Page 31 The title bar of AnxInit shows the MAC Address and IP Address of the currently selected AN-X. Set AN-X IP Configuration Utili

Seite 30 - Captured Data Format

Page 32 AN-X-AMXCAPT January 2008 Utilities/AN-X IP Configuration resets the selected AN-X. Use the Utilities/Restart AN-X to restart the AN-X

Seite 31 - AN-X-AMXCAPT Page 27

AN-X-AMXCAPT Page 33 Read Kernel Parameters The Utilities/Read Kernel Parameters command displays various communications parameters for the curre

Seite 32 - Using AnxInit

Page 34 AN-X-AMXCAPT January 2008 Update Firmware There are two ways to update all the firmware in an AN-X module. 1. The Configuration/Firm

Seite 33 - AN-X-AMXCAPT Page 29

AN-X-AMXCAPT Page 35 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the c

Seite 34 - Selecting an AN-X

Page 4 AN-X-AMXCAPT January 2008 Timestamps 16 Graphs 17 Frame Data 19 Detailed Status 19 Data Format 19 CRC 20 Equations 20 Keywords 2

Seite 35 - Set AN-X IP Configuration

Page 36 AN-X-AMXCAPT January 2008 The preferred method is to cycle power on the AN-X. Select the first option on the screen and click the Ne

Seite 36 - AN-X Info

AN-X-AMXCAPT Page 37 If the AN-X does not enter config mode within about 60 seconds, return to the previous screens and check the entries. Click

Seite 37 - Update AN-X Flash

Page 38 AN-X-AMXCAPT January 2008 This command resets the AN-X. You will receive a warning and be given the opportunity to Cancel the command.

Seite 38 - Update Firmware

AN-X-AMXCAPT Page 39 This command resets the AN-X. You will receive a warning and be given the opportunity to Cancel the command. You do not

Seite 39 - AN-X-AMXCAPT Page 35

Page 40 AN-X-AMXCAPT January 2008 Using the Web Interface The AN-X module contains a webserver capable of communicating with standard web brows

Seite 40

AN-X-AMXCAPT Page 41 Troubleshooting LEDs The AN-X-AMXCAPT has LEDs that indicate the state of the Ethernet connection, the overall module state

Seite 41 - Update Firmware Command

Page 42 AN-X-AMXCAPT January 2008 NET LED – Network Status The NET LED indicates the status of the AutoMax network. It operates only while the

Seite 42 - Patch Firmware

AN-X-AMXCAPT Page 43 Updating the Firmware The AN-X operating software consists of several parts: • boot code, runs at startup • configuration k

Seite 43 - AN-X-AMXCAPT Page 39

Page 44 AN-X-AMXCAPT January 2008 Specifications Parameter Specification Function Captures frames from AutoMax DCSNet or remote I/O network De

Seite 44 - Using the Web Interface

AN-X-AMXCAPT Page 45 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by ProSoft Technology

Seite 45 - Troubleshooting

View All Logs 40 Administration Menu 40 TROUBLESHOOTING 41 LEDs 41 Ethernet LEDs 41 SYS LED 41 NET LED – Network Status 42 UPDATING THE FIRMWA

Seite 46 - NET LED – Network Status

Page 46 AN-X-AMXCAPT January 2008 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material u

Seite 47 - Updating the Firmware

AN-X-AMXCAPT Module Overview This document is a user guide for the AN-X-AMXCAPT capture module. It connects to a computer using Ethernet and makes

Seite 48 - Specifications

AN-X-AMXCAPT Page 3 Package Contents • AN-X-AMXCAPT module • CD containing software and documentation Other Requirements To transfer data over

Seite 49 - Support

Page 4 AN-X-AMXCAPT January 2008 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! Ele

Seite 50 - Warranty

AN-X-AMXCAPT Page 5 The cable must be RG-59/U. Ethernet Cabling AN-X has a standard RJ-45 connector for connecting to Ethernet. If you are connec

Kommentare zu diesen Handbüchern

Keine Kommentare