PLX8x-EIP-61850 ♦ Communication Gateway Reference
Server to
IEC 61850 Client User Manual
ProSoft Technology, Inc. Page 83 of 167
July 2, 2015
5.2 Hardware Specifications PLX8x-EIP-61850
24 VDC nominal
10 to 32 VDC power input allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
200 mA maximum @ 24 VDC
150 mA maximum @ 32 VDC
450 mA maximum @ 10 VDC
32°F to 140°F (0°C to 60°C)
-40°F to 185°F (-40°C to 85°C)
5% to 95% RH, with no condensation
Standard: Height x Width x Depth
4.72 inches x 1.90 inches x 4.18 inches
10/100 Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP]
frames-per-second and less than or equal to 5 minutes duration
Shock and Vibration tested to EN 60068 Standard
One - Ethernet straight-through cable
One - J180 screw terminal plug
One - ProSoft Solutions DVD
One - HRD250 screwdriver
One - 1GB Industrial SD Card
5.3 LEDs
Power is not connected to the power terminals or source is
insufficient to properly power the gateway (800mA at 24 VDC
minimum required)
Power is connected to the power terminals. Verify that the other
LEDs for operational and functional status come on briefly after
power-up (check for burned-out LEDs).
A critical error has occurred. Program executable has failed or has
been user-terminated and is no longer running. Press Reset p/b or
cycle power to clear error.
The unit is in configuration mode. The configuration file is currently
being downloaded or, after power-up, is being read, the unit is
implementing the configuration values, and initializing the hardware.
This occurs during power cycle, or after pressing the reset button. It
also occurs after a cold/warm boot command is received.
An error condition has been detected and is occurring on one of the
application ports. Check configuration and troubleshoot for
communication errors.